Electrical Insulation System Component E200050
P LEO & CO LTD
4TH FL, UNIT 20-21, GOLDFIELD INDUSTRIAL CENTRE, FO TAN, 1 SUI WO RD, SHATIN N T HK
System Component System Designation System Class
1K063, 1K063CR, 1K1CR, 1K717, 1K7177, 1K7178, 1K7200, 1K7220, 1KPST, 1PEN2, 1PEN3, 1PN2R, 1PS25 F91 155(F)
report date: 2008-05-16 © 2017 UL LLC


Construction Details (Table I)
The use of this insulation system is limited to the combination of materials specified below. Where more than one item is designated under Insulation Function, they may be used together, unless otherwise indicated, or they may be used as alternates to one another. Functions designated "optional" are not necessarily required for every design. Insulation thicknesses and/or layers indicated below are minimum.
Note: Note: Insulated winding wires designated THL-F, THL-B, THL-E, THLX and THLY are suitable for use in this insulation system without additional ground or interwinding insulation
  Winding Wire - Recognized Component - Magnet wire (OBMW2), single build or greater, round or rectangular, copper or aluminum unless stated otherwise for the types listed below
- Recognized Component - Single and Multi-Layer Insulated Winding Wire (OBJT2) listed below
- Recognized Component - Appliance Wiring Material (AVLV2) listed below
- Bare conductors wrapped or interleaved with a paper or film listed below need not be a Recognized Component
(unless otherwise noted, winding wire types listed below may be used in combination within a single product)

ANSI TypeTemp(°C)Basecoat(Topcoat)
MW 30or180Polyester-amide-imide
MW 35or200Polyester-amide-imide (Polyamide-imide)
MW 36or200Polyester-amide-imide (Polyamide-imide)
MW 37or220Polyester (Polyamide-imide)
MW 38or220Polyester (Polyamide-imide)
MW 73or200Polyester-amide-imide (Polyamide-imide)
MW 74or200Polyester-amide-imide
MW 76or180Polyester-amide-imide (Polyamide)
MW 79or155Polyurethane
MW 80or155Polyurethane (Polyamide)
MW 82or180Polyurethane
MW 83or180Polyurethane (Polyamide)
 
Designationmils(mm)comments
HOI LUEN ELECTRICAL MFR CO LTD [E257525] - Recognized Component
THL-B-xx+, THL-B-SB-xx+3.9 (0.1)
THL-E-xx+3.9 (0.1)
THL-F-xx, THL-F-SB-xx3.9 (0.1)Reinforced insulation of ETFE minimum thickness


Ground & Interwinding Insulations
Designationmils(mm)comments
CELANESE INTERNATIONAL CORP [E344082] - Recognized Component
ZENITE 713011.8 (0.3)
ZENITE 9140HT(f1)11.8 (0.3)
ZENITE 9140HT(f2)11.8 (0.3)
E I DUPONT DE NEMOURS & CO INC [E41938] - Recognized Component
Rynite FR530(l)(+)(f1), FR530L(l)(+)(f1)15 (0.38)
Zytel HTNFR52G30LX15 (0.38)
Zytel HTNFR52G30NH(r6)15 (0.38)
E. I. Dupont de Nemours & Co.
Kapton CR1 (0.03)
Kapton HN1 (0.03)
P LEO & CO LTD [E126174] - Recognized Component
1K0631 [layers]
1K063CR1 [layers]
1K1CR1 [layers]
1K71771 [layers]
1K71781 [layers]
1K72001 [layers]
1K72201 [layers]
1KPST1 [layers]
1PEN21 [layers]
1PEN31 [layers]
1PN2R1 [layers]
1PS251 [layers]
P. Leo
1K7171 [layers]
SUMITOMO BAKELITE CO LTD [E41429] - Recognized Component
Sumikon PM-963011.8 (0.3)
Sumikon PM-982011.8 (0.3)
SUMITOMO CHEMICAL CO LTD [E249884] - Recognized Component
SUMIKASUPER E4008(c4)(c2)(c3)(j)(f2)15.7 (0.4)
TEIJIN FILM SOLUTIONS LIMITED [E206562] - Recognized Component
Teonex Film Q(l)(m), NQ(l)(m), K(l)(m)1 (0.03)
  


Any sheet insulation or tape described in this table with no minimum thickness requirement may be used as a Minor Sheet Material
Minor Sheet Materialslayer, outer, wrap etc.
minor sheet is optional for this system
Designationcomments
Dupont -Teijin Films
Teonex Q51
E I DUPONT DE NEMOURS & CO INC [E34739] - employing Recognized materials
Nomex® 410
Nomex® 411
Nomex® 414
Nomex® 416, 416 LAM
Nomex® 418, 818, 864LAM
Nomex® 464, 464 LAM
P. Leo
PB-2

Tapes
tapes are optional for this system
Designationcomments
P Leo & Co (B C) Ltd
1E075Additionally requires use of suitable Ground insulation in this system between metal foil and windings
1K7172silicone adhesive, polyimide film
1P830acrylic adhesive, polyester film
1P9FR
1PETS
1PG888
P LEO & CO LTD [E126174] - Listed or Recognized Component
1A025
1A570
1C821
1C822
1CC02
1G006
1G180
1G200
1G20B
1G220
1H818 (m)
1H850 Black (q)
1H850 Natural (o)
1H866 (g)
1H86A (o)
1H86R (g)
1K063
1K063CR
1K06A
1K125
1K1CR
1K220
1K7170
1K7177
1K7178
1K7200
1K7270
1KLMN
1KPST
1N012
1N155
1P350 (e)
1P700 (b)
1P701 (b)
1P702 (b)
1P703
1P705
1P756 (h)
1P801
1P802
1P802 (k)
1P802B
1P833xx (n)
1PEN2
1PEN3
1PG880 (o)
1PG887 (o)
1PN2R
1PN3R
1PN820 (o)
1PN828 (o)
1PS25
1TT02

Cores, Tubes, Bobbinsfor mechanical support only
Cores are optional for this system
Designationcomments
CHANG CHUN PLASTICS CO LTD [E59481] - employing Recognized materials
LONGLITE 4130(100%Virgin) (a)(b)
DSM Engineering Plastics
Akulon IG-S250F6
E I DUPONT DE NEMOURS & CO INC [E41938] - employing Recognized materials
Rynite FR330
Rynite FR515(f1)
Rynite FR530(l)(+)(f1), FR530L(l)(+)(f1)
Zytel 70G30L
Zytel 70G33HS1L(+)
Zytel 70G33HSL(+)
Zytel 70G33L(+)
Zytel FR50(+)(f1)
Any material described in this table with no thickness requirement may be used as a Spacer or a Wedge
Spacers & Wedges
spacers and wedges are optional for this system
Designationcomments
E. I. Dupont de Nemours & Co.
Nomex Board

Sleevings
sleevings are optional for this system
Designationcomments
P LEO & CO LTD [E176865] - Recognized Component
2S1yy-xx.x (a)
2S2yy-xx.x (a)
2T-TFL-xx.x (a)
2T-TFS-xx.x (a)
2T-TFT-xx.x (a)
P LEO & CO LTD [E195829] - Recognized Component
2R-SG#
2R-SG-1#
2R-SG-2#
2R-SG-3#
P. Leo
2R300
SUMITOMO ELECTRIC FINE POLYMER INC [E48762] - Recognized Component
811 or Sumitube F2
Sumitube F32


Varnishes
varnishes are optional for this system
Designationcomments
ELANTAS ELECTRICAL INSULATION ELANTAS PDG INC [E75225] - Recognized Component
468-2 (d), 468-2FC (d), 468-2-7-xxF (d), 468-2-7FC-xxF (d)
87V-456, 77X-010, 77X-010F
Isonel 31-398, Isonel 32RF, Isonel 31-863, Isonel 31-863X, Isonel 30
V1630, V1630FS, V1630FS50, V1630FS Black, 80361, 80361FCNot suitable for use with Polyurethane basecoat magnet wire Types MW79, MW80, MW82, MW83
Y-210, Y-210BLK, Y-210 BLACK, Y-210 Grey, Y-210PS Thermodur, EB 920
 
Potting Compounds
potting compounds are optional for this system
Designationcomments
SHIN-ETSU CHEMICAL CO LTD [E48923] - employing Recognized materials
KE-402(s)


 
Miscellaneous Minor Insulations
Misc. Minor Insulation is optional for this system
Designationcomments
GUANGDON SHENGYI SCI TECH CO LTD
S6015(b)FR-4 Core with Epoxy (EP) dielectric, High density interconnect - build up materials
Various Manufacturers
Recognized Component (QMTS2) Epoxy resin coated copper foil for use in multlayer printed wiring boardsin combination with ANSI Grade FR-4