OBJS2  System Component, Electrical Insulation - Component E200050  
P LEO & CO (B C) LTD
UNIT 150 12820 CLARKE PL RICHMOND BC V6V 2H1 CA
System
Component
System
Designation
System
Temp(Class)
1PEN2, 1PEN3, 1PN2R, 1K7177, 1K063, 1K7178, 1K7220, 1KPST, 1K7200, 1PS25, 1K063CR, 1K1CR, 1K717 F91 155(F)
Copyright © 2006 Underwriters Laboratories Inc.


Construction Details (Table I)  

The use of this insulation system is limited to the combination of materials specified below. Where more than one item is designated under Insulation Function, they may be used together, unless otherwise indicated, or they may be used as alternates to one another. Functions designated "optional" are not necessarily required for every design. Insulation thicknesses and/or layers indicated below are minimum.
Note: Note: Insulated winding wires designated THL-F, THL-B, THL-E, THLX and THLY are suitable for use in this insulation system without additional ground or interwinding insulation

  Winding Wire - Recognized Component - Magnet wire (OBMW2), single build or greater, round or rectangular  listed below or
- Recognized Component - Single and Multi-Layer Insulated Winding Wire (OBJT2) listed below or
- Recognized Component - Appliance Wiring Material (AVLV2) listed below
- Bare conductors wrapped or interleaved with a paper or film listed below need not be a Recognized Component
(unless otherwise noted, winding wire types listed below may be used in combination within a single product)
MW 30 or 180C Polyester-amide-imide
MW 35 or 200C polyester (polyamideimide)
MW 36 or 200C Polyester (Polyamide-imide)
MW 37 or 220C Polyester (Polyamide-imide)
MW 38 or 220C Polyester (Polyamide-imide)
MW 73 or 200C Polyester-amide-imide (Polyamide-imide)
MW 74 or 200C Polyester-amide-imide
MW 76 or 180C Polyester (Polyamide)
MW 79 or 155C Polyurethane
MW 80 or 155C Polyurethane (Polyamide)
MW 82 or 180C Polyurethane
MW 83 or 180C Polyurethane (Polyamide)

Hoi Luen Electrical Mfr Co Ltd
     THL-B3.9 mils (0.1 mm)
     THL-E3.9 mils (0.1 mm)
     THL-F3.9 mils (0.1 mm)
     THLX3.9 mils (0.1 mm)
     THLY3.9 mils (0.1 mm)
Ground & Interwinding Insulations
     Designation (no.)mils(mm)comments
Dupont Teijin Films
     Teonex Q511 (0.03)PEN
E. I. Dupont de Nemours & Co.
     Kapton CR1 (0.03)
     Kapton HN1 (0.03)
     Rynite FR53015 (0.38)polyethylene terephthalate (PET)
     Zenite 713011.8 (0.3)
     Zenite 9140HT11.8 (0.3)
     Zytel HTNFR52G30LX15 (0.38)
     Zytel HTNFR52G30NH15 (0.38)
P. Leo
     1K063 1 (layers)Recognized Component - Insulating Tape (OANZ2)
     1K063CR 1 (layers)
     1K1CR 1 (layers)
     1K717 1 (layers)
     1K7177 1 (layers)Recognized Component - Insulating Tape (OANZ2)
     1K7178 1 (layers)
     1K7200 1 (layers)
     1K7220 1 (layers)Recognized Component - Insulating Tape (OANZ2)
     1KPST 1 (layers)
     1PEN2 1 (layers)Recognized Component - Insulating Tape (OANZ2)
     1PEN3 1 (layers)Recognized Component - Insulating Tape (OANZ2)
     1PN2R 1 (layers)Recognized Component - Insulating Tape (OANZ2)
     1PS25 1 (layers)
Sumitomo Bakelite
     E400815.7 (0.4)
     Sumikon PM-963011.8 (0.3)Phenolic Molding Compound
     Sumikon PM-982011.8 (0.3)Phenolic Molding Compound

Minor Sheet Insulations(optional)layer, outer, wrap etc.
Any sheet insulation or tape described in this table with no minimum thickness requirement.
     Designation (no.)comments
Dupont -Teijin Films
     Teonex Q51
E. I. Dupont de Nemours & Co.
     Nomex 410
     Nomex 411
     Nomex 414
     Nomex 416
     Nomex 418
     Nomex 464
P. Leo
     PB-2
Cores, Tubes Bobbins(optional)for mechanical support only
     Designation (no.)comments
Chang Chun
     PBT-4130
     T375J
     T376J
DSM Engineering Plastics
     Akulon IG-S250F6
E. I. Dupont de Nemours & Co.
     Rynite FR330
     Rynite FR515
     Rynite FR530
     Rynite FR530L
     Zytel 70G30L
     Zytel 70G33HSIL
     Zytel 70G33HSL
     Zytel 70G33Lglass filled polyamide Type 66 nylon
     Zytel FR50
Tapes(optional)
     Designation (no.)comments
P Leo & Co (B C) Ltd
     1A025
     1A570
     1C821 cotton cloth
     1C822
     1CC02
     1E075 Additionally requires use of suitable Ground insulation in this system between metal foil and windings
     1G006 aramid fiber (Nomex) paper
     1G180 glass cloth
     1G200 woven glass cloth, silicone adhesive
     1G20B
     1G220
     reinforced PET, rubber adhesive 1H818
     1H850 polyester film
     1H866 PET film with nonwoven polyester reinforcement fibers, acrylic adhesive
     1H86A
     1H86R
     1K063 silicone adhesive, polyimide film
     1K063CR
     1K06A
     1K125
     1K1CR
     1K220
     1K717
     1K7170 Kapton film
     1K7172 silicone adhesive, polyimide film
     1K7177 Kapton film
     1K7178
     1K7200
     1K7270 Kapton film
     1KLMN
     1KPST
     1N012 Aramid fiber (Nomex), Acrylic Adhesive
     1N155 Aramid fiber (Nomex), Acrylic Adhesive
     1P350 PET film, acrylic adhesive
     1P700 polyester film
     1P701 polyester film
     1P702 polyester film
     1P703 polyester film
     1P705 polyester film
     1P756
     1P801 acrylic adhesive, polyester film
     1P802 acrylic adhesive, polyester film
     1P802B
     1P830 acrylic adhesive, polyester film
     1P833 PET film, acrylic adhesive
     1P9FR
     1PEN2
     1PEN2R
     1PEN3
     1PEN3R
     1PETS
     1PG880 polyester film glass laminate
     1PG887 polyester film glass laminate
     1PG888
     1PN820 woven polyester cloth
     1PN828 woven polyester cloth
     1PS25
     1TT02
   
Spacers and Wedges(optional)
 
     Designation (no.)comments
E. I. Dupont de Nemours & Co.
     Nomex Board
Sleevings(optional)
     Designation (no.)comments
P. Leo
     2R-SG
     2R-SG-1
     2R-SG-2
     2R-SG-3
     2R300
     2S1@@-xx.xxHeat Shrinkable
     2S1WH-xx.xxHeat Shrinkable
     2S2@@-xx.xxHeat Shrinkable
     2S2WH-xx.xxHeat Shrinkable
     2T-TFL
     2T-TFS
     2T-TFT
Sumitomo
     Sumitube F2
     Sumitube F32
Varnishes(optional)Recognized Component - Varnishes (OBOR2)
     Designation (no.)comments
Elantas Deatech S R L / P.D. George
     80361FS
     80831FC Not suitable for use with Polyurethane basecoat magnet wire Types MW79, MW80, MW82, MW83
     Y210
Elantas Deatech S R L / P.D. George / Ripley Resin
     468-2(+)(+) may be proceed by prefix "E" and may be followed by a one to five alphanumeric suffix indicating % inert filler and/or color
Elantas Deatech S R L / P.D. George / Schenectady
     Isonel 31-398
Elantas Deatech S R L / P.D. George / Sterling
     77X-010
Potting Compounds(optional)
     Designation (no.)comments
Shin Etsu
     KE402
 
Miscellaneous Minor Insulations(optional)
     Designation (no.)comments
GUANGDON SHENGYI SCI TECH CO LTD
     S6015(b)FR-4 Core with Epoxy (EP) dielectric, High density interconnect - build up materials
Various Manufacturers
     Recognized Component (QMTS2) Epoxy resin coated copper foil for use in multlayer printed wiring boardsin combination with ANSI Grade FR-4
  

NOTICE : This information , based upont UL Testing Guidelines and our experience, is offered without charge by P. Leo as part of our service to customers. It is intended for persons having technical skill to use at their own discretion and risk. We do not guarantee favorable results, and the P. Leo & Co., (B.C.) Ltd. assumes no obligation or liability for any advice furnished or for any results obtained to operae under, or a recommendation to infringe upon, any patent of P. Leo or others. Compliance with applicable government codes is also the responsibility of the user.


® Registered trademark of Underwriters Laboratories, Inc.

Copyright © 1996-2007 P. Leo & Co., Ltd.

All rights reserved. Reproduction in whole or in part in any form or medium without express written permission of P. Leo & Co., Ltd. is prohibited.

BCwire ; pBobbin ; BCmica; BCtube are trademarks of P. Leo & Co.(B.C.), Ltd.

Zytel ® Rynite ® Zenite® Kapton ® Kaladex ® Mylar ® and Nomex ® are Du Pont trade marks.